Technologies -

CEMTEK Optical Measurement Systems

Optical Based Process and Compliance Measurements

The successful operations of the ceramic filter technology in both the industrial and marine environment has driven adoption of disruptive technology including both Tunable Diode Laser (TDL) and Differential Optical Absorption Spectrometer (DOAS) based analyzers. These technologies provide high accuracy at a lower cost than traditional extractive CEMS with the features and advantages listed below.

Features and Advantages for TDL and DOAS

The diagram shows the basic components of each system and most importantly shows the absence of sample lines, calibration gas cylinders, gas conditioning panels, and a dedicated shelter.

Specifications
Path Length Up to 2 meters
Dynamic Range 5 orders of magnitude
Response Time 0.1 seconds and higher
Calibration Factory set
Light Source Deuterium lamp/Xe Arc lamp
Air Purge 0 to 15 L/min
Operating Conditions
Source Gas Optics
-100 to 1,800 C -40 to 65 C
5-95% RH 5-95% RH
25-2,000 mbar 25-2000 mbar
System Sensitivities
GasDetection LimitGasDetection Limit
 ppbv ppbv
NO600O335
NO275Benzene170
NH310Toluene600
SO2300HCHO3000
SO3500  

These non extractive systems are incorporated into all of the projects developed by Precision Partners and have proven to provide superior accuracy, with much less maintenance, resulting in less downtime, less operating cost, and at a lower initial installed cost than traditional CEMS for more than 10 years. The technology was and continues to be refined by Unisearch Inc out of Toronto Canada and fully turnkey systems are designed, fabricated, and delivered by our technology partner, CEMTEK KVB-Enertec.

 

For more information please contact us at Precision Partners directly or contact our technology partner CEMTEK.